Skip to content

Outdoor Instrument Transformers

Outdoor Current Transformers

Manufactured for dependable protection, metering and measurement in outdoor substations and industrial power systems. INDULF manufactures oil-immersed current transformers up to 33 kV, configured to your required ratio, accuracy class, burden and insulation level.

Voltage class

UP TO 33 kV

Primary current

UP TO 3000 A

Outdoor oil-filled current transformer on its mounting base, porcelain insulator stack below the tank

Overview

Precision in every transformer. Confidence in every installation.

Outdoor current transformers are a critical link between the primary power system and the protection and metering equipment that monitors it. INDULF manufactures oil-immersed outdoor CTs for substations, feeders and industrial power systems, with each transformer configured around the required ratio, accuracy class, burden, insulation level and core arrangement.

Our manufacturing approach combines controlled production with application-specific engineering, ensuring every transformer is built to deliver consistent electrical performance and dependable service in outdoor installations. From winding and insulation systems to assembly, finishing and final inspection, quality is maintained throughout the manufacturing process — not only at the point of dispatch.

Testing is an integral part of that process. INDULF maintains in-house testing capabilities with NABL-accredited facilities, enabling electrical performance and routine checks to be verified before dispatch. Our transformers are also supplied for approved applications across North Indian states, supporting utility, industrial, infrastructure and EPC requirements with the technical documentation required for inspection, approval and commissioning.

  • Manufactured to application-specific requirements
  • In-house testing with NABL-accredited capability
  • Technical documentation supplied for inspection, approval and commissioning
Outdoor oil-filled current transformer on its mounting base
Outdoor substation grid infrastructure
Row of outdoor current transformers staged for dispatch

What we manufacture

A CT range built around your application

From outdoor protection to revenue metering, INDULF manufactures CT configurations for the measurement and protection requirements of substations, feeders, industrial systems and infrastructure projects.

Up to 33 kV

Outdoor Oil-Immersed CTs

For substations, feeders and outdoor installations.

Protection

Protection-Class CTs

Designed for reliable relay operation and accurate current reproduction during fault conditions.

Metering

Metering-Class CTs

Built for accurate measurement in metering, monitoring and revenue-related applications.

Dual-core

Metering + Protection CTs

Two functions in one transformer, combining metering and protection cores where the application requires both.

Technical capability

Built to meet your project requirements

INDULF outdoor current transformers are manufactured across a range of voltage, current, accuracy and core configurations to suit protection, metering and measurement applications.

Voltage class

01

Up to 33 kV

Outdoor Oil-Immersed

Primary current rating

02

Up to 3000 A

Configured to application

Rated burden

03

As Per Requirement

Selected for connected circuit

Accuracy class

04

0.1 / 0.2 / 0.2S / 0.5 / 0.5S / 1 / 3 / 5

Metering and protection classes

Core

05

Metering / Protection / Multi-core

Single or multi-core configurations

Standards

06

As per IEC 61869, IEC 60044, ANSI/IEEE

Product and project requirements

Why INDULF

From manufacturing to final testing, we control the process

Every INDULF transformer reflects controlled manufacturing, rigorous testing and a commitment to consistent quality and dependable performance.

  • 01

    CONTROLLED MANUFACTURING

    Our instrument transformers are manufactured with controlled processes for winding, insulation, assembly and finishing, maintaining consistency from production through final inspection.

  • 02

    APPLICATION-LED ENGINEERING

    Each transformer is configured around the required ratio, accuracy class, burden, insulation level and core arrangement for its intended protection or metering application.

  • 03

    IN-HOUSE TESTING

    Every transformer is subjected to defined routine checks before dispatch through our in-house NABL-accredited testing facility.

  • 04

    QUALITY AT EVERY STAGE

    Quality is maintained through defined inspection and control processes across materials, manufacturing, assembly and final inspection.

Find the right instrument transformer

Explore More from INDULF

Next step

Outdoor substation grid infrastructure

Request a quote

Your Requirement. Our Manufacturing Capability.

Share your project requirement, specification or single-line diagram with our team. We'll review the application, confirm the appropriate CT configuration and provide the technical and commercial details you need to move forward.

  • 01We review your electrical requirement and identify the appropriate CT configuration for the application.
  • 02Ratio, accuracy class, burden, core arrangement and other key parameters are confirmed before production.
  • 03The completed transformer is tested and supplied with the technical documentation required for your project.

Manufacturing range

Available specifications & configurations

The key parameters that define the performance and configuration of each outdoor current transformer.

Outdoor Current Transformers, specification range by parameter
ParameterAvailable configurations
Type
  • Outdoor
  • Oil Immersed
  • Epoxy Resin
Rated system voltage
  • 11 kV
  • 22 kV
  • 33 kV
Rated primary current
  • Up to 2000 A
Rated secondary current
  • 1 A
  • 5 A
Rated output burden
  • 5 VA
  • 15 VA
Accuracy class — metering
  • 0.2S
  • 0.2
  • 0.5S
  • 0.5
  • 1.0
  • 2.0
Accuracy class — protection
  • 5P
  • 10P
Rated frequency
  • 50 Hz
  • 60 Hz
Number of cores
  • Up to 5
Construction
  • Dead tank (bottom tank)
  • Live tank (top tank)